24. ISO 26262 6-6

24.1. 6-6 Specification of Software Safety Requirements

24.1.1. 6.4.1

  • Requirements Management

  • Requirements are directly on unit level, no overall safety requirements as these are independent library functionalities

24.1.2. 6.4.2

Covered by Requirements Management.

24.1.2.1. 6.4.2.a

See 6.4.2.

24.1.2.2. 6.4.2.b

See 6.4.2.

24.1.2.3. 6.4.2.c

See 6.4.2.

24.1.2.4. 6.4.2.d

See 6.4.2.

24.1.2.5. 6.4.2.e

See 6.4.2.

24.1.2.6. 6.4.2.f

See 6.4.2.

24.1.2.7. 6.4.2.g

See 6.4.2.

24.1.3. 6.4.3

Not applicable, all ASIL B, no decomposition

24.1.4. 6.4.4

Not applicable, no hardware-software interface, SW only component, HW assumptions are clearly stated on Certification Scope

24.1.5. 6.4.5

Not applicable, only safety related functions

24.1.6. 6.4.6

Not applicable, no hardware-software interface, SW only component, HW assumptions are clearly stated on Certification Scope

24.1.7. 6.4.7

Same as IEC 61508-3 7.2.2.3 argument, no real requirements on this level, more unit level specification/requirements, see 6-8.

24.1.7.1. 6.4.7.a

See above

24.1.7.2. 6.4.7.b

Not applicable, SW SEooC, no technical safety requirements/concept

24.1.7.3. 6.4.7.c

Not applicable, SW SEooC, no system level

24.1.7.4. 6.4.7.d

Not applicable, SW SEooC, no HSI