18. ISO 26262 Applicable clausesΒΆ
Clause |
Applicable |
Rationale |
|---|---|---|
2-5 Overall Safety Management |
Yes |
|
2-6 Project Dependent Safety M. |
Yes |
|
2-7 Production-Operation-Servi |
Yes |
|
3-5 Item Definition |
No |
SW SEooC, no Item level |
3-6 Hazard Analysis |
No |
SW SEooC, no Item level |
3-7 Functional Safety Concept |
No |
SW SEooC, no Item level |
4-5 Product Development SYS Lev |
No |
SW SEooC, no system level |
4-6 Technical Safety Concept |
No |
SW SEooC, no system level |
4-7 Sys Integration and Testing |
No |
SW SEooC, no system level |
4-8 Safety Validation |
No |
SW SEooC, no system level |
5-5 Development on HW Level |
No |
SW SEooC, no hardware level |
5-6 Spec of HW Safety Requirem. |
No |
SW SEooC, no hardware level |
5-7 Hardware Design |
No |
SW SEooC, no hardware level |
5-8 Evaluation of HW Metrics |
No |
SW SEooC, no hardware level |
5-9 Safety Goal Violations |
No |
SW SEooC, no hardware level |
5-10 HW Integration and Verifi. |
No |
SW SEooC, no hardware level |
5-C Architectural Metrics |
No |
SW SEooC, no hardware level |
6-5Product Development SW Level |
Yes |
|
6-6 SW Safety Requirements |
Yes |
|
6-7 SW Architectural Design |
Yes |
|
6-8 SW Unit Design and Implemen |
Yes |
|
6-9 SW Unit Verification |
Yes |
|
6-10 SW Integration&Verificatio |
Yes |
|
6-11 Testing of Embedded SW |
Yes |
|
6-C Configurable Software |
No |
The core library is delivered as a pre-compiled library. There is no way to configure the core library binary after it is compiled and linked on targets without dynamic loaders (currently this applies to all qualified cross-compilation targets). |
7-5 Planning for P, O, S, D |
No |
SW SEooC, no hardware level |
7-6 Production |
No |
SW SEooC, no hardware level |
7-7 Operation, Service & Decom. |
Tailored |
Only Field Monitoring and Safety instructions applicable |
8-5 Interfaces |
No |
No distributed development / DIA, therefore not applicable |
8-6 Safety Requirements |
Yes |
|
8-7 Configuration Management |
Yes |
|
8-8 Change Management |
Yes |
|
8-9 Verification |
Yes |
|
8-10 Documentation Management |
Yes |
|
8-11 Use of Softwaretools |
Yes |
|
8-12 Qualification of SW Compo |
No |
Qualification not applied, handled as new development |
8-13 Evaluation of HW Elements |
No |
SW SEooC, no hardware level |
8-14 Proven in Use Argument |
No |
Not used |
8-15 Interfacing an Application |
No |
SW SEooC, no system level |
8-16 Integration of Safety Rel. |
No |
SW SEooC, no system level |
9-5 Requirements Decomposition |
No |
Not used, all ASIL B |
9-6 Coexistence of Elements |
No |
Only a single element of ASIL B, therefore no coexistence |
9-7 Analysis of Dependent Failures |
No |
No dependencies*, single ASIL component, therefore tailored |
9-8 Safety Analyses |
No |
No architectural level, single component, no further analysis required |
12-5 Adaption for Motorcycles |
No |
No motorcycles in scope |
12-6 Safety Culture |
No |
No motorcycles in scope |
12-7 Confirmation Measures |
No |
No motorcycles in scope |
12-8 Hazard Analysis and Risk A |
No |
No motorcycles in scope |
12-9 Vehicle Integration&Testing |
No |
No motorcycles in scope |
12-10 Safety Validation |
No |
No motorcycles in scope |