18. ISO 26262 Applicable clausesΒΆ

Clause

Applicable

Rationale

2-5 Overall Safety Management

Yes

2-6 Project Dependent Safety M.

Yes

2-7 Production-Operation-Servi

Yes

3-5 Item Definition

No

SW SEooC, no Item level

3-6 Hazard Analysis

No

SW SEooC, no Item level

3-7 Functional Safety Concept

No

SW SEooC, no Item level

4-5 Product Development SYS Lev

No

SW SEooC, no system level

4-6 Technical Safety Concept

No

SW SEooC, no system level

4-7 Sys Integration and Testing

No

SW SEooC, no system level

4-8 Safety Validation

No

SW SEooC, no system level

5-5 Development on HW Level

No

SW SEooC, no hardware level

5-6 Spec of HW Safety Requirem.

No

SW SEooC, no hardware level

5-7 Hardware Design

No

SW SEooC, no hardware level

5-8 Evaluation of HW Metrics

No

SW SEooC, no hardware level

5-9 Safety Goal Violations

No

SW SEooC, no hardware level

5-10 HW Integration and Verifi.

No

SW SEooC, no hardware level

5-C Architectural Metrics

No

SW SEooC, no hardware level

6-5Product Development SW Level

Yes

6-6 SW Safety Requirements

Yes

6-7 SW Architectural Design

Yes

6-8 SW Unit Design and Implemen

Yes

6-9 SW Unit Verification

Yes

6-10 SW Integration&Verificatio

Yes

6-11 Testing of Embedded SW

Yes

6-C Configurable Software

No

The core library is delivered as a pre-compiled library. There is no way to configure the core library binary after it is compiled and linked on targets without dynamic loaders (currently this applies to all qualified cross-compilation targets).

7-5 Planning for P, O, S, D

No

SW SEooC, no hardware level

7-6 Production

No

SW SEooC, no hardware level

7-7 Operation, Service & Decom.

Tailored

Only Field Monitoring and Safety instructions applicable

8-5 Interfaces

No

No distributed development / DIA, therefore not applicable

8-6 Safety Requirements

Yes

8-7 Configuration Management

Yes

8-8 Change Management

Yes

8-9 Verification

Yes

8-10 Documentation Management

Yes

8-11 Use of Softwaretools

Yes

8-12 Qualification of SW Compo

No

Qualification not applied, handled as new development

8-13 Evaluation of HW Elements

No

SW SEooC, no hardware level

8-14 Proven in Use Argument

No

Not used

8-15 Interfacing an Application

No

SW SEooC, no system level

8-16 Integration of Safety Rel.

No

SW SEooC, no system level

9-5 Requirements Decomposition

No

Not used, all ASIL B

9-6 Coexistence of Elements

No

Only a single element of ASIL B, therefore no coexistence

9-7 Analysis of Dependent Failures

No

No dependencies*, single ASIL component, therefore tailored

9-8 Safety Analyses

No

No architectural level, single component, no further analysis required

12-5 Adaption for Motorcycles

No

No motorcycles in scope

12-6 Safety Culture

No

No motorcycles in scope

12-7 Confirmation Measures

No

No motorcycles in scope

12-8 Hazard Analysis and Risk A

No

No motorcycles in scope

12-9 Vehicle Integration&Testing

No

No motorcycles in scope

12-10 Safety Validation

No

No motorcycles in scope